First, fill in the blanks
1. The circuit consists of three components: ________, ________, and ________.
2. The intermediate links in the circuit (such as transformers, transmission and distribution lines, and switchgear, etc.) function as _____ and _______.
3. In the circuit, the connection form of the resistor is _____, _____, _____.
4. Three-phase and three-phase loads of three-phase power supply. The common connection methods are ____ connection and ______ connection.
5. The power supply to the underground coal mine is prohibited from directly grounding the neutral point, so it is called the ____ system.
6, the multimeter can mainly measure ____, ______, ___, _____ and ____.
7, Megger (also called shake table) is used to measure wires, cables and transformers, distribution, and electrical equipment ______.
8. Under normal circumstances, the mine power supply should adopt a split operation mode. When one circuit ____, the other circuit must be _______ standby.
9. Insulation appliances for substation rooms include ______, _______ and __________.
10. The _________ support is applied to the substation of the mining area, and the fireproof iron door to the ___ must be installed in the diverticulum.
11. The location and space of the power distribution point of the mining face must meet the requirements of ____ and _____, mine car passing and other equipment installation, and expand with _________.
12. When the length of the substation chamber exceeds _____ meters, an outlet must be provided at each end of the chamber.
13, the underground must be qualified by _______ and obtained coal mine products _____ flame retardant cable.
14. The cable suspension height in the roadway should ensure that the cable is not impacted when it is _____, and does not fall on one or ________ when the cable falls.
15. When the cable and the air duct and the water supply pipe are laid on the same side of the roadway, they must be laid on the pipe ____ side and keep the distance above ________ meters.
16. In gas spilling areas, high gas mines, coal (rock) and gas (carbon dioxide) outburst mines, the local ventilator for the excavation face should be powered by three specialties. The three specialties refer to _____, ________, _________.
17. The pressure local ventilation fan and starting device must be installed in the ______ roadway, and the return air inlet from the roadway should not be less than _____ meters.
18. The local ventilator of the low gas mine heading face can be powered by the line equipped with ______ or with _______.
19. When the local fan is stopped due to a fault, it must be _______, _________.
20. Gas must be checked before the local ventilator is ventilated. The local ventilator can only be manually turned on if the gas concentration in the airflow within _______ meters is not exceeded between the local ventilator and its switch.
21, the underground power supply cable connection should be "three no", that is, no ________, no _________ and no _________.
22. The spacing of cable suspension points shall not exceed _____ meters in horizontal or inclined shafts and shall not exceed ______ meters in the main shaft.
23. When the high and low power cables are located on the same side of the roadway, the distance between the high and low voltage cables should be greater than _______ meters.
24, the cable through the wall part of the application ________ protection, and __________.
25, the three major protections of underground electrical means ____ protection, _____ protection, ______ protection.
26. Comprehensive underground protection includes ________ comprehensive protection and ____ comprehensive protection.
27. In the operation of low-voltage power grids, common overcurrent faults are _____, ____ and ____.
28, explosion-proof electrical equipment before the well, should check its _____, ______ and ____ and safety performance.
29. The functions of the comprehensive protection device of the coal power station include ______, ______, _______, _______, _______ to start and stop the coal electric drill remotely.
30. Communication and signal cables and power cables in the roadway should be hung on both sides of the roadway. If conditions are limited, they should be laid above the power cable _____ meters above.
31. The coal mining face scraper conveyor must be equipped with a device that can send a stop and start signal. The distance between the signals should not exceed ____ meters.
32. Before the operation of the skid machine, the sensor of the methane power-off instrument must be suspended above the _____.
33. The mobile machine for mining the working face must be _______ immediately after the end of each shift and when the driver leaves the machine, and open ________.
34. When the concentration of gas in the wind at the mining face and other working sites reaches 1.0%, it must be _____________.
35. When the gas concentration in the airflow within 20 meters of the motor or its switch installation site in the mining face and other working sites reaches 1.5%, it must be ______, ___________, ___________, ______________.
36. For electrical equipment whose power supply is cut off in excess of the specified concentration, the gas concentration must be reduced to ______ or less before the power can be turned on.
37. After the gas is discharged from the wind stop area, only the gas in the ventilation flow of the restored ventilation shall not exceed _____ and the concentration of carbon dioxide shall not exceed ______, then the power supply and the electrical equipment of the electric equipment in the roadway of the local ventilator shall be restored. Power supply in the district return air system.
38. Without the mine safety monitoring system, the non-gas-flowing rock road heading face must be equipped with ______ locking device and coal mining face equipment ________.
39. Coal roadways, semi-coal rock roadways and mine face with gas mine gushing mines that are not equipped with mine safety monitoring system must be equipped with _________ locking devices or _______ and __________ locking devices.
40. In the inclined lane of the truck lift, the principle of __________, __________ should be adhered to.
41. Common cables in underground are divided into ________ cable, ________ cable and ______ cable.
42. Selecting the cable section is generally calculated by _____, that is, the actual operating current flowing through the cable must be less than or equal to the allowed ________.
43. The general mark of explosion-proof electrical equipment is _____.
44. Explosion of explosion-proof electrical equipment means that the explosion-proof casing of mining electrical equipment has lost ___ sex or ________.
45. Any explosion-proof electrical equipment that has been blasted must be __________ and must not be in the underground ___________.
46. Overloading means that the current actually flowing through the electrical equipment exceeds its _____ current and exceeds _______.
47. High-voltage control equipment for downhole high-voltage motors and power transformers shall have _____, ________, __________ and ___________ protection functions.
48. _______, ________ and _________ protection devices shall be installed on the feeders from the substation substation, mobile substation or distribution point.
49. The control equipment of the low-voltage motor shall have _________, ________, _______, _________ protection devices and remote control devices.
50, _________, __________, other electromechanical chambers and several horizontal grid connection ground should be set _______.
51. The operational reliability of the electrical equipment protection device means that when the line and electrical equipment are faulty, the protection device should be able to operate reliably without ________ and ___ actions.
52. The level of intrinsically safe electrical equipment is divided into two levels: _______ and _______. Coal mines generally use ________ level.
53. When the high and low voltage power cables are laid on the same side of the roadway, the distance between the high and low voltage power cables should be greater than _____ meters. The distance between the high voltage cables and the low voltage cables should not be less than ______ mm.
54. The basic requirements for mine electrical protection devices are ____________, ____________, __________ and ____________.
55. Voltage protection includes _____________ and ________________.
56. The flameproof principle of flameproof electrical equipment includes ____ sex and _________ sex.
57. Ordinary portable electrical measuring instruments must be used at a location below the gas concentration _____.
58. Non-professional personnel and ________ shall not operate underground electrical equipment without authorization.
Motor of 59, 40Kw and above shall be controlled by ____________.
60. When operating the main circuit of high-voltage electrical equipment, the operator must _______, and ______ or stand on the insulation platform.
Second, multiple choice questions
1. The following power users (powered devices) belong to the first-level user (), and belong to the second-level user ().
A, mining substation B, main ventilator C, main shaft lifting equipment D for lifting personnel, rectification equipment E for underground electric vehicle, air compressor station F, main drainage pump G, mine hospital H, passenger tram
2. Cables must be used from the substation of the mining area to the distribution point of the mining face. ()
A, aluminum package B, copper core C, aluminum core
3. In the outburst area of gas emission, high gas mine, coal (rock) and gas (carbon dioxide), the local ventilator of the excavation face should be powered by ().
A, three special (special transformer, special switch, special line) B, power supply circuit C with selective leakage protection device, separate from the coal mining face
4. The control button of the shearer must be set on the () side and a protective cover.
A. By the coal wall B, by the goaf C, above the unit
5. When the mobile electric locker goes down, it must carry portable ().
A, optical methane detector B, methane detector C, methane detection alarm
6. The coal roadway, semi-coal rock roadway and mine roadway with gas mines that do not have the mine safety monitoring system must be equipped ().
A, methane power-off instrument B, methane wind power blocking device C, methane power-off device and wind power blocking device
7. The electric fitter in the coal and gas outburst mine should be equipped with () self-rescuer.
A, filter B, compression C, chemical oxygen
8. When a fire occurs in a single-headed alley, the local fan that is operating should ().
A, stop running B, keep running
9. It is strictly forbidden to use the local ventilator above () to supply air to a boring work surface at the same time.
A, 2 B, 3 C, 4
10. When the gas concentration in the airflow within 20 meters near the motor and its switch installation location reaches (), the work must be stopped, the power supply must be cut off, and the personnel should be evacuated for disposal.
A, 1.0% B, 1.5% C, 2.0%
11, the mine one pass three anti-finger to strengthen ventilation, anti-gas, fire, ().
A, anti-cold top B, waterproof disaster C, anti-dust
12. The transformer should be selected in a mine with a gas explosion hazard.
A, oil immersion B, mine explosion-proof dry C, power transformer
13. The calculation method of short-circuit current is ().
A, economic current method B, formula method C, graphic method
14. Electrical equipment should be used for lighting fixtures in the return airway of the mining area of the high gas mine.
A, mine general type B, mine explosion-proof type C, mine increased safety type
15. High-voltage motors in the main air intake of high gas mines should be equipped with () electrical equipment.
A, mine general type B, mine explosion-proof type C, mine increased safety type
16. In the mining face and other roadways, when the accumulated gas concentration in the space larger than 0.5ms reaches (), the work must be stopped within 20 meters, the power supply is cut off, and the personnel are evacuated for treatment.
A, 1.0% B, 1.5% C, 2.0% D, 5.0%
17. After the exhaust gas is exhausted, the power supply of the electrical equipment in the air supply duct of the local ventilator and the power supply in the return air system of the mining area can be manually restored only when the gas concentration in the airflow of the restored ventilation tunnel does not exceed ().
A, 0.5% B, 1.0% C, 1.5%
18. For electrical equipment whose power supply is cut off in excess of the specified concentration, the gas concentration must be reduced to () meters or less before the power can be turned on.
A, 0.5% B 1.0% C, 1.5%
19. The minimum electrical clearance for electrical equipment with a voltage of 220V shall be mm.
A, 4 B, 6 C, 8
20. In the circuit with two resistors connected in parallel, the calculation formula of the equivalent resistance R should be ().
A, R = R1 + R2 B, R = R1 × R2 / (R1 + R2)
C, 1/R: 1/R1+1/R2
21, in the gas mine, measuring the grounding resistance commonly used ().
A, buck type B, power method C, special resistance tester method
D, bridge method
22. When measuring the AC voltage with a multimeter, the black test pen should be inserted into the () jack.
A, "one" B, "ten"
23. The voltage protection of underground electrical equipment includes ().
A, under voltage protection B, single phase voltage protection C, over voltage protection
24. When measuring the circuit voltage with a multimeter, the instrument should be phased with the load.
A, series B, series or parallel C, parallel
25. Mobile and hand-held electrical equipment should use () cable.
A, rubber sleeve B, MVV type plastic force C special rubber sleeve
26. The fireproof iron door of the electromechanical chamber should be opened.
A, inward B, outward C, inward or outward
27, explosion-proof gas equipment before the well, should check its product certificate, explosion-proof certificate, () and safety performance.
A, production license B, safety sign C, safety license
28. The coal electric drill comprehensive protection device shall conduct a trip test every ().
• A, class B, day C, week
29. Ordinary belt electrical measuring instruments must be used below the gas concentration ().
A, 0.5% B, 1•0% C, 1.5%
30. In the coal flow face, the oxygen concentration shall not be lower than ()
A, 18% B, 20% C, 21%
Third, the judgment question
1. The current of each series resistor in the series circuit is the same, and the total resistance is the sum of the respective resistors. ()
2. The voltage across the resistors in the parallel circuit is equal to the power supply voltage, and the total resistance is the sum of the sub-resistors ()
3. When measuring voltage and current with a multimeter, do not touch the transfer switch with power. ()
4. The "Procedure" stipulates that under normal circumstances, the mine power supply should adopt a split operation mode. When the first circuit is running, the other circuit can be used without power to ensure the continuity of the power supply ()
5. It is strictly forbidden to install a load doser on the mine power line. ()
6. The other loads on the two-circuit power line of the mine must be reported to the mine manager for approval. ()
7. The neutral point of the distribution transformer under the forbidden well is directly grounded. ()
8. When repairing or relocating electrical equipment and cables, it is necessary to cut off the power supply and check the gas. When the gas concentration in the roadway is less than 1.5%, use the electroscope that matches the power supply. If the inspection is invalid, the conductor can be used. Discharge to the ground. ()
9. Megohmmeter is an instrument used to measure the insulation resistance and voltage of wires, cables and transformers, electrical equipment and electrical equipment. ()
10. The protection ring of the shaker is connected to the negative pole of the generator through the wire, so as to avoid the surface leakage power of the insulator affecting the measurement result. ()
11. When a local ventilator supplies air to two boring faces working at the same time, safety measures must be taken. ()
12. In the high-voltage circuit, the isolating switch cannot break the load current, and only the circuit breaker can break the load current. ()
13. Mine low-voltage feed switch is a kind of manual closing power supply switch. When the line has over-current and leakage faults, it can automatically trip to cut off the power. ()
14. When the cable and the air duct are installed on the side of the roadway, the cable should be firmly suspended under the air duct, but it is strictly prohibited to hang any objects on the cable. ()
15. When the cable is laid on the same side as the gas drainage pipeline, the cable should be laid on the pipe and kept at a distance of more than 3 meters. ()
16. The winding lane of the lift personnel and the winch lanes used for lifting materials and pedestrians shall not exceed 30 meters. ()
17, underground explosion-proof type of communication, signal and control devices, should be preferred to use mining increased safety. () (Editor: Electrician Network)
18. The explosion of explosion-proof electrical equipment means that the mining electrical equipment loses its flameproofness. ()
19. Clearance is the shortest air distance between two bare conductors. ()
20. Creepage distance is the shortest distance between two conductors along the surface of a solid material. ()
21. The basic requirement for the setting of the operating current of the electromagnetic overcurrent relay in the low-voltage power grid is that the protection should be able to operate reliably when the minimum two-phase short circuit occurs in the protected equipment. ()
22. Overvoltage refers to the phenomenon that the voltage that threatens the insulation of electrical equipment rises more than 20% of the rated voltage during the operation of the power supply system. ()
23, the over-voltage of coal mine underground can be divided into operating over-voltage, arc-grounding over-voltage and resonant over-voltage according to its nature. ()
24. The "Procedure" stipulates that the metal casing, the frame, the steel strip or the steel wire of the armored cable or the lead wire or the shield sheath of the electrical equipment which may be dangerously damaged due to insulation damage must have protective grounding. ()
25. The local grounding electrode installed in the ditch shall be not less than 0,6m2, and the thickness shall not be less than 2mm steel plate or steel pipe with the same effective area. ()
26. It is forbidden to connect several devices in series, but several grounding parts can be connected in series. ()
27. Safety spark-type instruments should be used when measuring downhole grounding resistance in mines with gas and coal dust explosion hazards. ()
28. It is strictly forbidden to use bulbs for heating and using electric furnaces. ()
29, when the electrical equipment is on fire, the power should be cut off first, before the power is cut off, only use non-conductive fire-fighting equipment to extinguish the fire. ()
30. The underground flow electric fitter must carry a portable gas detection alarm. ()
31. Filter self-rescuing devices must be worn when mines with coal and gas outburst dangers. ()
32. The underground electrician must pass the training and obtain the special work operation qualification certificate and be certified to work. ()
33. It is strictly forbidden to enter the roadway without ventilation or poor ventilation. ()
34. Located in the electromechanical chamber of the return air flow, the gas concentration in this return air flow shall not exceed 1.0%. ()
35. The concentration of hydrogen in the downhole charging chamber airflow and local accumulation shall not exceed 0.5%. ()
36. When using the local ventilation fan to vent the working face, when the wind is stopped due to maintenance or power failure, the personnel must be evacuated and the power supply must be cut off. ()
37. Before the local ventilator that has stopped running for some reason, the gas must be inspected. Only when the gas concentration in the airflow within 10 meters of the local ventilator and its switch does not exceed 1%, the local ventilation can be manually turned on. machine. ()
38. For electrical equipment whose power supply is cut off in excess of the specified concentration, the gas concentration must be reduced to 1, 0% or less before powering on. ()
39. When the gas concentration in the airflow within 20 meters near the motor or its switch installation site reaches 1%, it must stop working, cut off the power supply, and evacuate the personnel for disposal. ()
40. It is strictly forbidden to work in the area where the wind is stopped or the gas is out of limits. ()
41. Underground explosive materials must be equipped with explosion-proof (except mine-enhanced type) lighting equipment. It is strictly forbidden to install lamps in the chamber or wall tank where explosive materials are stored. ()
42. The lighting voltage of the underground explosive material library shall not exceed 220V. ()
43. No one may carry a miner's lamp into the underground explosive material store. ()
44. When multi-level transportation of inclined wells, the signals sent by each level must be different. ()
45. Explosion-proof electrical equipment should be inspected before the well, and the “product certificateâ€, “explosion-proof certificateâ€, “coal mine product safety mark†and safety performance should be checked. ()
46. Pipes that are introduced (exited) from the track and open-air overhead of the direct manhole on the ground must have a good centralized grounding of the metal body at not less than two places near the wellhead. ()
47. Communication lines must be equipped with fuses and lightning protection devices at the wells. ()
48. When a single-loop power supply is used for a mine with an annual output of less than 60,000 tons, there must be a backup power supply; the capacity of the backup power supply must meet the requirements for drainage and lifting;
49. The operation of the low-pressure leak detection device must be tested once a week. ()
50. The five major natural disasters in coal mines refer to disasters such as roof, gas, fire, electricity and water. ()
Fourth, the question and answer questions
1. What are the principles for selecting the cross section of the cable?
2. What are the requirements for power supply to the local ventilator?
3. What should you pay attention to when using a megohmmeter?
4. How to identify the non-flame-retardant rubber cable for mining on the ground?
5. How to determine the cable phase-to-phase short circuit fault?
6. Briefly explain the causes and preventive measures of cable phase failure.
7. What is the explosion of explosion-proof electrical equipment?
8. What regulations should be followed for operating downhole electrical equipment?
9. What regulations should be followed for maintenance or relocation of underground electrical equipment?
10. What are the causes of common phase-to-phase short-circuit faults?
11. What are the main hazards of leakage faults?
12. What is the role of protective grounding?
13, a switch with 10Kw motor, the system voltage is 660v, the power factor of the motor is: 0.86, please choose to protect the melt of the motor.
14. How does shielded cable improve power supply security?
15. What are the links and main equipment of the mine power supply system?
16. What are the main primary loads in coal mines?
17. What are the characteristics of the resistor parallel circuit?
18. What are the components of the underground protective earthing network?
19. What are the regulations on the location and space of the distribution points of the mining face?
20. How can I become a qualified electrician?
Answers to the underground electrician test questions 1. Fill in the blanks:
1, power, load, intermediate links
2, transmission voltage, power distribution
3, series, parallel, mixed
4, star (Y), triangle (厶)
5, three-phase three-wire
6, DC current, DC voltage, AC current, AC voltage, resistance
7, insulation resistance
8, running, charged
9, insulated boots, insulated gloves, insulation
10, non-combustible materials, outside
11. Equipment maintenance, roadway transportation, non-combustible materials
1 B 6
13, inspection, safety signs,
14, mine car drop, track, conveyor
15, up, 0. 3
16, special transformer, special switch, dedicated line
17, the wind, 10
18. The power supply line and coal mining face of the selective leakage protection device are separated.
19. Withdraw personnel and cut off the power supply
20, 10, 0, 5%
21, chicken paws, sheep tail, Ming joints
22, 3, 6
128
23, 0, 1,
24, casing, tight sealing pipe
25, overcurrent, grounding, leakage
26, electric motor, coal electric drill (lighting)
27, short circuit, overload, single phase disconnection
28, product certification, explosion-proof certificate, coal mine product safety signs
29, leak detection, leakage lockout, short circuit, overload, phase failure
30, 0, 1
31, 15 ,
32. Bucket operation section
33, cut off the power supply, clutch
34, stop using the electric drill to drill
35, stop working, cut off the power, evacuate personnel, handle
36, 1,0%
37, 1, 0%, 1, 5%, manual
38. Wind power and methane power-off instrument
39. Methane wind power, methane power-off instrument and wind power lockout
40, pedestrians do not drive, driving is not pedestrian
41, armor, plastic, mining rubber
42. Economic current method, long-term load current
43, EX,
44, explosion-proof, explosion-proof
45, prohibited use, long-term storage
46, rated, allowed overcurrent time
47, short circuit; overload, grounding, undervoltage release
48, short circuit, overload, leakage
49, short circuit, overload, single phase disconnection, leakage lock
50. Mining substation, mining area distribution point, auxiliary grounding bus
51, refused to move, mistake
129
Selectivity, rapidity, sensitivity, operational reliability, undervoltage protection, overvoltage protection, explosion-proof, explosion-proof
1, 0%
Non-on-duty electrical personnel vacuum electromagnetic detonators,
Wear insulated gloves and wear electrician insulated boots.
1, BCFG, ADE, 2, B, 3, AB, 4, B, 5, B, 6, BC,
7, BC, 8, B, 9, B, 10, B, 11, C, 12, AB, 13,
BC, 14, BC, 15, B, 16, C, 17, B, 18, B, 19, B,
20, CB, 21, C, 22, A, 23, AC, 24, C, 25, C,
26, B, 27, B, 28, A, 29, B, 30, B
Third, the judgment question:
1, √, 2, X, 3, √, 4, X, 5, √, 6, X, 7, √, 8,
X, 9, X, 10, √, 11, X, 12, √, 13, √, 14, X,
15, X, 16, √, 17, X, 18, X, 19, √, 20, √, 21,
X,22, X,23, √,24, X,25, X,26, X,27, √,
28, √, 29, √, 30, X, 31, X, 32, √, 33, √, 34,
X, 35, √, 36, √, 37, X, 38, √, 39, √, 40, √,
41, √, 42, X, 43, √, 44, √, 45, √, 46, √, 47,
√, 48, √, 49, X, 50, X.
Fourth, the question and answer questions
1. Answer: When selecting the cable cross section, the following four principles should be observed:
(1) When the cable is in normal operation, the temperature rises.
(2) Select according to the allowable voltage loss when the cable line I is used.
(3) The cable cross section should be selected to meet the mechanical strength requirements.
(4) The minimum two-phase short-circuit current at the end of the cable should be greater than the set current value of the feed switch.
2. Answers: The “Safety Regulations for Coal Mines†stipulates that: “Gas spouting area, high gas mine, coal (rock) and gas (carbon dioxide) protruding in the mine, the local ventilator of the excavation working face shall adopt three special (special transformer, special Switch, special line) power supply; power supply line with selective leakage protection device can also be used, but every day should be checked by a special person to ensure reliable operation of the local fan.†The local ventilators of the two adjacent roadways can be powered by a set of “three special†equipment, or they can be powered by two sets of low-voltage lines. However, a local ventilator must not supply air to two heading faces.
3, A: Note:
(1) The speed of the measuring time meter should be kept at 120r/rain or constant.
(2) When the three terminals of the megohmmeter lead out of the line, do not entangle each other, it is best to use a single strand.
(3) The megohmmeter voltage should be compatible with the voltage level of the device under test.
(4) When measuring equipment with large capacitance, such as large motor or long cable insulation, the initial charging current is large, and the indication value of the shaking table pointer is small, but this does not mean that the equipment under test is poorly insulated. It must be after a certain period of time, and the reading can be accurate after the pointer is stable.
4. A: In order to facilitate the management of the non-flame retarding performance of the mine rubber sheathed flexible cable, it is usually possible to make a reference discrimination on the ground for the non-flammability of the rubber sheath. The method is as follows:
(1) Using an electrician knife at the end of the cable to be tested, but with a length of 200 mm, a width of 10 mm, and a thickness of 2 soils of 0,3 mm, the end of the cable is clamped with an electrician's pliers, and the narrow side is downward;
(2) Burning with an alcohol lamp or an alcohol-burning lamp with a flame height of not less than 50 mm
131
52, ia, ib, ib
53, 0, 1, 50
54. Selectivity, rapidity, sensitivity, and operational reliability
55, under voltage protection, over voltage protection
56, explosion-proof, explosion-proof
57, 1, 0%
58. Non-duty electrical personnel
59. Vacuum electromagnetic detonator
60, wear insulated gloves, wear electrician insulated boots, two, multiple choice questions:
1, BCFG, ADE, 2, B, 3, AB, 4, B, 5, B, 6, BC,
7, BC, 8, B, 9, B, 10, B, 11, C, 12, AB, 13,
BC, 14, BC, 15, B, 16, C, 17, B, 18, B, 19, B,
20, CB, 21, C, 22, A, 23, AC, 24, C, 25, C,
26, B, 27, B, 28, A, 29, B, 30, B
Third, the judgment question: